A close command is only the start

A power-operated door can receive a close command without successfully reaching a closed and locked state. The train therefore needs feedback about the result. The Thessaloniki Metro rolling-stock specification describes propulsion inhibition until the doors are closed and locked, together with a door loop whose open state prevents normal departure. This is a documented design example rather than a universal circuit diagram. Its logic makes the distinction clear: the command requests an action, while the indication reports whether the required door state has been achieved.

Sources: door-metro

The movement itself supplies clues

An obstruction can make an electric door work harder or prevent it from completing the expected movement. The same metro specification calls for motor-current monitoring, movement/time monitoring and an electrical sensitive-edge switch. These offer different observations of the closing process rather than one interchangeable signal. The specified response to a detected obstruction is reopening, with persistent obstruction ultimately leaving the door open. Such functions concern the moving door and its interaction with an object; they do not, by themselves, explain everything a closed-door indication can prove.

Sources: door-metro

The seal can become a sensing element

A door’s flexible edge has a mechanical job as well as a possible sensing role. Wabtec’s description of its asymmetrical anti-drag device combines a shaped door seal with a sensitive edge continuously monitored by the door control unit. The geometry is intended to distinguish an external dragging hazard from interference originating inside the vehicle. That is a more specific design objective than simply measuring how much current the closing motor draws. The physical shape of the seal helps determine which interaction reaches the sensor.

Sources: door-wabtec

Detection can continue after closure

The moment when the leaves finish moving does not have to end the safety assessment. IFE describes anti-drag equipment intended to recognise hazardous trapping with the door already closed and prevent the train from starting. Its ProDect 2S description identifies detection from both inside and outside the vehicle. This illustrates a separate layer of sensing aimed at the closed-door condition. It is a capability of the documented equipment, not evidence that every train carries it or that any possible trapped item will always be detected.

Sources: door-ife

Closed and locked does not mean unobstructed

RAIB’s investigations show why the distinction matters. Thin objects can remain trapped in doors that have reached their closed and locked state without being detected by the door-control system. The interlock indication can consequently be correct about the door mechanism while failing to establish that nothing is caught. This is a limitation of what the indication represents, not merely a question of whether a lamp works. Door-position proof, lock proof and obstruction detection answer related but different questions about the same doorway.

Sources: door-raib

The final departure check covers a wider scene

A train can have its doors closed while a person or object is still in an unsafe relationship with the vehicle. RAIB’s learning summary identifies cases in which staff treated interlock indications as assurance that nothing was trapped. It also discusses the importance of the final safety check and the limitations of viewing arrangements. The engineering boundary is useful to understand: door sensors provide evidence about defined conditions at the mechanism, while departure assurance must address what is happening at the wider platform–train interface.

Sources: door-raib